The
tensile test was carried out on extracted welded and unwelded specimens using
universal testing machine (UTM). Microstructures of the welded specimens were
carried out and analyzed. Statistical analysis (ANOVA) and signal to noise
ratio were used to study the significant effect of input parameters on ultimate
tensile strength and optimized conditions for the process performance
respectively. The results showed that experiment number 7 has the highest
ultimate tensile strength (UTS) of 487MPa and S/N ratio of 53.74 dB. The S/N
ratio of higher value indicates better characteristic of optimum MMAW process
performance. The study shows that the optimum condition is A3B1C3D2 at welding
current 100A, electrode angle of 700, root gap of 3.3 mm and a welding speed of
3.6 mm/s .